C     ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
C
C     mach.f - part of the SLAP linear algebra library
C
C     This library is in the public domain.
C
C     ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
C
      REAL FUNCTION R1MACH(I)
C
C  SINGLE-PRECISION MACHINE CONSTANTS
C
C  R1MACH(1) = B**(EMIN-1), THE SMALLEST POSITIVE MAGNITUDE.
C
C  R1MACH(2) = B**EMAX*(1 - B**(-T)), THE LARGEST MAGNITUDE.
C
C  R1MACH(3) = B**(-T), THE SMALLEST RELATIVE SPACING.
C
C  R1MACH(4) = B**(1-T), THE LARGEST RELATIVE SPACING.
C
C  R1MACH(5) = LOG10(B)
C
C  TO ALTER THIS FUNCTION FOR A PARTICULAR ENVIRONMENT,
C  THE DESIRED SET OF DATA STATEMENTS SHOULD BE ACTIVATED BY
C  REMOVING THE C FROM COLUMN 1.
C  ON RARE MACHINES A STATIC STATEMENT MAY NEED TO BE ADDED.
C  (BUT PROBABLY MORE SYSTEMS PROHIBIT IT THAN REQUIRE IT.)
C
C  WHERE POSSIBLE, OCTAL OR HEXADECIMAL CONSTANTS HAVE BEEN USED
C  TO SPECIFY THE CONSTANTS EXACTLY WHICH HAS IN SOME CASES
C  REQUIRED THE USE OF EQUIVALENT INTEGER ARRAYS.
C
      INTEGER SMALL(2)
      INTEGER LARGE(2)
      INTEGER RIGHT(2)
      INTEGER DIVER(2)
      INTEGER LOG10(2)
C
      REAL RMACH(5)
C
      EQUIVALENCE (RMACH(1),SMALL(1))
      EQUIVALENCE (RMACH(2),LARGE(1))
      EQUIVALENCE (RMACH(3),RIGHT(1))
      EQUIVALENCE (RMACH(4),DIVER(1))
      EQUIVALENCE (RMACH(5),LOG10(1))
C
C     MACHINE CONSTANTS FOR THE BURROUGHS 1700 SYSTEM.
C
C      DATA RMACH(1) / Z400800000 /
C      DATA RMACH(2) / Z5FFFFFFFF /
C      DATA RMACH(3) / Z4E9800000 /
C      DATA RMACH(4) / Z4EA800000 /
C      DATA RMACH(5) / Z500E730E8 /
C
C     MACHINE CONSTANTS FOR THE BURROUGHS 5700/6700/7700 SYSTEMS.
C
C      DATA RMACH(1) / O1771000000000000 /
C      DATA RMACH(2) / O0777777777777777 /
C      DATA RMACH(3) / O1311000000000000 /
C      DATA RMACH(4) / O1301000000000000 /
C      DATA RMACH(5) / O1157163034761675 /
C
C     MACHINE CONSTANTS FOR THE CDC 6000/7000 SERIES.
C
C      DATA RMACH(1) / 00014000000000000000B /
C      DATA RMACH(2) / 37767777777777777777B /
C      DATA RMACH(3) / 16404000000000000000B /
C      DATA RMACH(4) / 16414000000000000000B /
C      DATA RMACH(5) / 17164642023241175720B /
C
C     MACHINE CONSTANTS FOR CONVEX C-1
C
C      DATA RMACH(1) / '00800000'X /
C      DATA RMACH(2) / '7FFFFFFF'X /
C      DATA RMACH(3) / '34800000'X /
C      DATA RMACH(4) / '35000000'X /
C      DATA RMACH(5) / '3F9A209B'X /
C
C     MACHINE CONSTANTS FOR THE CRAY 1
C
C      DATA RMACH(1) / 200034000000000000000B /
C      DATA RMACH(2) / 577767777777777777776B /
C      DATA RMACH(3) / 377224000000000000000B /
C      DATA RMACH(4) / 377234000000000000000B /
C      DATA RMACH(5) / 377774642023241175720B /
C
C     MACHINE CONSTANTS FOR THE DATA GENERAL ECLIPSE S/200
C
C     NOTE - IT MAY BE APPROPRIATE TO INCLUDE THE FOLLOWING CARD -
C     STATIC RMACH(5)
C
C      DATA SMALL/20K,0/,LARGE/77777K,177777K/
C      DATA RIGHT/35420K,0/,DIVER/36020K,0/
C      DATA LOG10/40423K,42023K/
C
C     MACHINE CONSTANTS FOR THE HARRIS SLASH 6 AND SLASH 7
C
C      DATA SMALL(1),SMALL(2) / '20000000, '00000201 /
C      DATA LARGE(1),LARGE(2) / '37777777, '00000177 /
C      DATA RIGHT(1),RIGHT(2) / '20000000, '00000352 /
C      DATA DIVER(1),DIVER(2) / '20000000, '00000353 /
C      DATA LOG10(1),LOG10(2) / '23210115, '00000377 /
C
C     MACHINE CONSTANTS FOR THE HONEYWELL DPS 8/70 SERIES.
C
C      DATA RMACH(1) / O402400000000 /
C      DATA RMACH(2) / O376777777777 /
C      DATA RMACH(3) / O714400000000 /
C      DATA RMACH(4) / O716400000000 /
C      DATA RMACH(5) / O776464202324 /
C
C     MACHINE CONSTANTS FOR AT&T 3B SERIES MACHINES.
C
C      DATA SMALL(1) /     8388608 /
C      DATA LARGE(1) /  2139095039 /
C      DATA RIGHT(1) /   864026624 /
C      DATA DIVER(1) /   872415232 /
C      DATA LOG10(1) /  1050288283 /
C
C     MACHINE CONSTANTS FOR THE IBM PC AND OTHER 8087-ARITHMETIC MICROS
C
C      DATA SMALL(1) /     8388608 /
C      DATA LARGE(1) /  2139095039 /
C      DATA RIGHT(1) /   864026624 /
C      DATA DIVER(1) /   872415232 /
C      DATA LOG10(1) /  1050288283 /
C
C     MACHINE CONSTANTS FOR THE IBM 360/370 SERIES,
C     THE XEROX SIGMA 5/7/9 AND THE SEL SYSTEMS 85/86.
C
C      DATA RMACH(1) / Z00100000 /
C      DATA RMACH(2) / Z7FFFFFFF /
C      DATA RMACH(3) / Z3B100000 /
C      DATA RMACH(4) / Z3C100000 /
C      DATA RMACH(5) / Z41134413 /
C
C     MACHINE CONSTANTS FOR THE INTERDATA 8/32
C     WITH THE UNIX SYSTEM FORTRAN 77 COMPILER.
C
C     FOR THE INTERDATA FORTRAN VII COMPILER REPLACE
C     THE Z'S SPECIFYING HEX CONSTANTS WITH Y'S.
C
C      DATA RMACH(1) / Z'00100000' /
C      DATA RMACH(2) / Z'7EFFFFFF' /
C      DATA RMACH(3) / Z'3B100000' /
C      DATA RMACH(4) / Z'3C100000' /
C      DATA RMACH(5) / Z'41134413' /
C
C     MACHINE CONSTANTS FOR THE PDP-10 (KA OR KI PROCESSOR).
C
C      DATA RMACH(1) / "000400000000 /
C      DATA RMACH(2) / "377777777777 /
C      DATA RMACH(3) / "146400000000 /
C      DATA RMACH(4) / "147400000000 /
C      DATA RMACH(5) / "177464202324 /
C
C     MACHINE CONSTANTS FOR PDP-11 FORTRANS SUPPORTING
C     32-BIT INTEGERS (EXPRESSED IN INTEGER AND OCTAL).
C
C      DATA SMALL(1) /    8388608 /
C      DATA LARGE(1) / 2147483647 /
C      DATA RIGHT(1) /  880803840 /
C      DATA DIVER(1) /  889192448 /
C      DATA LOG10(1) / 1067065499 /
C
C      DATA RMACH(1) / O00040000000 /
C      DATA RMACH(2) / O17777777777 /
C      DATA RMACH(3) / O06440000000 /
C      DATA RMACH(4) / O06500000000 /
C      DATA RMACH(5) / O07746420233 /
C
C     MACHINE CONSTANTS FOR PDP-11 FORTRANS SUPPORTING
C     16-BIT INTEGERS  (EXPRESSED IN INTEGER AND OCTAL).
C
C      DATA SMALL(1),SMALL(2) /   128,     0 /
C      DATA LARGE(1),LARGE(2) / 32767,    -1 /
C      DATA RIGHT(1),RIGHT(2) / 13440,     0 /
C      DATA DIVER(1),DIVER(2) / 13568,     0 /
C      DATA LOG10(1),LOG10(2) / 16282,  8347 /
C
C      DATA SMALL(1),SMALL(2) / O000200, O000000 /
C      DATA LARGE(1),LARGE(2) / O077777, O177777 /
C      DATA RIGHT(1),RIGHT(2) / O032200, O000000 /
C      DATA DIVER(1),DIVER(2) / O032400, O000000 /
C      DATA LOG10(1),LOG10(2) / O037632, O020233 /
C
C     MACHINE CONSTANTS FOR THE SUN MICROSYSTEMS UNIX F77 COMPILER.
C
      DATA RMACH(1) / 1.17549435E-38 /
      DATA RMACH(2) / 3.40282347E+38 /
      DATA RMACH(3) / 5.96016605E-08 /
      DATA RMACH(4) / 1.19203321E-07 /
      DATA RMACH(5) / 3.01030010E-01 /
C
C     MACHINE CONSTANTS FOR THE Alliant FX/8 UNIX Fortran COMPILER
C     WITH THE -r8 COMMAND LINE OPTION.  This option causes all variables
c     declared with 'real' to be of type 'real*8' or double precision.
c     This option does not override the 'real*4' declarations.  These
c     R1MACH numbers below and the coresponding I1MACH are simply the double
c     precision or 'real*8' numbers.  If you use the -r8 your whole code
c     (and the user libraries you link with, the system libraries are taken
c     care of automagicly) must be compiled with this option.
C
c$$$      DATA RMACH(1) / 2.22507385850721D-308 /
c$$$      DATA RMACH(2) / 1.79769313486231D+308 /
c$$$      DATA RMACH(3) / 1.1101827117665D-16 /
c$$$      DATA RMACH(4) / 2.2203654423533D-16 /
c$$$      DATA RMACH(5) / 3.01029995663981E-1 /
C
C     MACHINE CONSTANTS FOR THE UNIVAC 1100 SERIES.
C
C      DATA RMACH(1) / O000400000000 /
C      DATA RMACH(2) / O377777777777 /
C      DATA RMACH(3) / O146400000000 /
C      DATA RMACH(4) / O147400000000 /
C      DATA RMACH(5) / O177464202324 /
C
C     MACHINE CONSTANTS FOR THE VAX UNIX F77 COMPILER
C
C      DATA SMALL(1) /       128 /
C      DATA LARGE(1) /    -32769 /
C      DATA RIGHT(1) /     13440 /
C      DATA DIVER(1) /     13568 /
C      DATA LOG10(1) / 547045274 /
C
C     MACHINE CONSTANTS FOR THE VAX-11 WITH
C     FORTRAN IV-PLUS COMPILER
C
C      DATA RMACH(1) / Z00000080 /
C      DATA RMACH(2) / ZFFFF7FFF /
C      DATA RMACH(3) / Z00003480 /
C      DATA RMACH(4) / Z00003500 /
C      DATA RMACH(5) / Z209B3F9A /
C
C     MACHINE CONSTANTS FOR VAX/VMS VERSION 2.2
C
C      DATA RMACH(1) /       '80'X /
C      DATA RMACH(2) / 'FFFF7FFF'X /
C      DATA RMACH(3) /     '3480'X /
C      DATA RMACH(4) /     '3500'X /
C      DATA RMACH(5) / '209B3F9A'X /
C
C     MACHINE CONSTANTS FOR THE SEQUENT BALANCE 8000 AND SVS FORTRAN ON
C     THE AT&T 7300 (UNIX PC)
C
C      DATA SMALL(1) / $00800000 /
C      DATA LARGE(1) / $7F7FFFFF /
C      DATA RIGHT(1) / $33800000 /
C      DATA DIVER(1) / $34000000 /
C      DATA LOG10(1) / $3E9A209B /
C
C     MACHINE CONSTANTS FOR RM FORTRAN (ON THE AT&T 7300)
C
C      DATA RMACH(1) / Z'00800000' /
C      DATA RMACH(2) / Z'7F7FFFFF' /
C      DATA RMACH(3) / Z'33800000' /
C      DATA RMACH(4) / Z'34000000' /
C      DATA RMACH(5) / Z'3E9A209B' /
C
C
      IF (I .LT. 1  .OR.  I .GT. 5) GOTO 999
      R1MACH = RMACH(I)
      RETURN
  999 WRITE(I1MACH(2),1999) I
 1999 FORMAT(' R1MACH - I OUT OF BOUNDS',I10)
      STOP
      END
      DOUBLE PRECISION FUNCTION D1MACH(I)
C
C  DOUBLE-PRECISION MACHINE CONSTANTS
C
C  D1MACH( 1) = B**(EMIN-1), THE SMALLEST POSITIVE MAGNITUDE.
C
C  D1MACH( 2) = B**EMAX*(1 - B**(-T)), THE LARGEST MAGNITUDE.
C
C  D1MACH( 3) = B**(-T), THE SMALLEST RELATIVE SPACING.
C
C  D1MACH( 4) = B**(1-T), THE LARGEST RELATIVE SPACING.
C
C  D1MACH( 5) = LOG10(B)
C
C  TO ALTER THIS FUNCTION FOR A PARTICULAR ENVIRONMENT,
C  THE DESIRED SET OF DATA STATEMENTS SHOULD BE ACTIVATED BY
C  REMOVING THE C FROM COLUMN 1.
C  ON RARE MACHINES A STATIC STATEMENT MAY NEED TO BE ADDED.
C  (BUT PROBABLY MORE SYSTEMS PROHIBIT IT THAN REQUIRE IT.)
C
C  WHERE POSSIBLE, OCTAL OR HEXADECIMAL CONSTANTS HAVE BEEN USED
C  TO SPECIFY THE CONSTANTS EXACTLY WHICH HAS IN SOME CASES
C  REQUIRED THE USE OF EQUIVALENT INTEGER ARRAYS.
C
      INTEGER SMALL(4)
      INTEGER LARGE(4)
      INTEGER RIGHT(4)
      INTEGER DIVER(4)
      INTEGER LOG10(4)
C
      DOUBLE PRECISION DMACH(5)
C
      EQUIVALENCE (DMACH(1),SMALL(1))
      EQUIVALENCE (DMACH(2),LARGE(1))
      EQUIVALENCE (DMACH(3),RIGHT(1))
      EQUIVALENCE (DMACH(4),DIVER(1))
      EQUIVALENCE (DMACH(5),LOG10(1))
C
C     MACHINE CONSTANTS FOR THE BURROUGHS 1700 SYSTEM.
C
C      DATA SMALL(1) / ZC00800000 /
C      DATA SMALL(2) / Z000000000 /
C
C      DATA LARGE(1) / ZDFFFFFFFF /
C      DATA LARGE(2) / ZFFFFFFFFF /
C
C      DATA RIGHT(1) / ZCC5800000 /
C      DATA RIGHT(2) / Z000000000 /
C
C      DATA DIVER(1) / ZCC6800000 /
C      DATA DIVER(2) / Z000000000 /
C
C      DATA LOG10(1) / ZD00E730E7 /
C      DATA LOG10(2) / ZC77800DC0 /
C
C     MACHINE CONSTANTS FOR THE BURROUGHS 5700 SYSTEM.
C
C      DATA SMALL(1) / O1771000000000000 /
C      DATA SMALL(2) / O0000000000000000 /
C
C      DATA LARGE(1) / O0777777777777777 /
C      DATA LARGE(2) / O0007777777777777 /
C
C      DATA RIGHT(1) / O1461000000000000 /
C      DATA RIGHT(2) / O0000000000000000 /
C
C      DATA DIVER(1) / O1451000000000000 /
C      DATA DIVER(2) / O0000000000000000 /
C
C      DATA LOG10(1) / O1157163034761674 /
C      DATA LOG10(2) / O0006677466732724 /
C
C     MACHINE CONSTANTS FOR THE BURROUGHS 6700/7700 SYSTEMS.
C
C      DATA SMALL(1) / O1771000000000000 /
C      DATA SMALL(2) / O7770000000000000 /
C
C      DATA LARGE(1) / O0777777777777777 /
C      DATA LARGE(2) / O7777777777777777 /
C
C      DATA RIGHT(1) / O1461000000000000 /
C      DATA RIGHT(2) / O0000000000000000 /
C
C      DATA DIVER(1) / O1451000000000000 /
C      DATA DIVER(2) / O0000000000000000 /
C
C      DATA LOG10(1) / O1157163034761674 /
C      DATA LOG10(2) / O0006677466732724 /
C
C     MACHINE CONSTANTS FOR THE CDC 6000/7000 SERIES.
C
C      DATA SMALL(1) / 00604000000000000000B /
C      DATA SMALL(2) / 00000000000000000000B /
C
C      DATA LARGE(1) / 37767777777777777777B /
C      DATA LARGE(2) / 37167777777777777777B /
C
C      DATA RIGHT(1) / 15604000000000000000B /
C      DATA RIGHT(2) / 15000000000000000000B /
C
C      DATA DIVER(1) / 15614000000000000000B /
C      DATA DIVER(2) / 15010000000000000000B /
C
C      DATA LOG10(1) / 17164642023241175717B /
C      DATA LOG10(2) / 16367571421742254654B /
C
C     MACHINE CONSTANTS FOR CONVEX C-1
C
C      DATA SMALL(1),SMALL(2) / '00100000'X, '00000000'X /
C      DATA LARGE(1),LARGE(2) / '7FFFFFFF'X, 'FFFFFFFF'X /
C      DATA RIGHT(1),RIGHT(2) / '3CC00000'X, '00000000'X /
C      DATA DIVER(1),DIVER(2) / '3CD00000'X, '00000000'X /
C      DATA LOG10(1),LOG10(2) / '3FF34413'X, '509F79FF'X /
C
C     MACHINE CONSTANTS FOR THE CRAY 1
C
C      DATA SMALL(1) / 201354000000000000000B /
C      DATA SMALL(2) / 000000000000000000000B /
C
C      DATA LARGE(1) / 577767777777777777777B /
C      DATA LARGE(2) / 000007777777777777776B /
C
C      DATA RIGHT(1) / 376434000000000000000B /
C      DATA RIGHT(2) / 000000000000000000000B /
C
C      DATA DIVER(1) / 376444000000000000000B /
C      DATA DIVER(2) / 000000000000000000000B /
C
C      DATA LOG10(1) / 377774642023241175717B /
C      DATA LOG10(2) / 000007571421742254654B /
C
C     MACHINE CONSTANTS FOR THE DATA GENERAL ECLIPSE S/200
C
C     NOTE - IT MAY BE APPROPRIATE TO INCLUDE THE FOLLOWING CARD -
C     STATIC DMACH(5)
C
C      DATA SMALL/20K,3*0/,LARGE/77777K,3*177777K/
C      DATA RIGHT/31420K,3*0/,DIVER/32020K,3*0/
C      DATA LOG10/40423K,42023K,50237K,74776K/
C
C     MACHINE CONSTANTS FOR THE HARRIS SLASH 6 AND SLASH 7
C
C      DATA SMALL(1),SMALL(2) / '20000000, '00000201 /
C      DATA LARGE(1),LARGE(2) / '37777777, '37777577 /
C      DATA RIGHT(1),RIGHT(2) / '20000000, '00000333 /
C      DATA DIVER(1),DIVER(2) / '20000000, '00000334 /
C      DATA LOG10(1),LOG10(2) / '23210115, '10237777 /
C
C     MACHINE CONSTANTS FOR THE HONEYWELL DPS 8/70 SERIES.
C
C      DATA SMALL(1),SMALL(2) / O402400000000, O000000000000 /
C      DATA LARGE(1),LARGE(2) / O376777777777, O777777777777 /
C      DATA RIGHT(1),RIGHT(2) / O604400000000, O000000000000 /
C      DATA DIVER(1),DIVER(2) / O606400000000, O000000000000 /
C      DATA LOG10(1),LOG10(2) / O776464202324, O117571775714 /
C
C     MACHINE CONSTANTS FOR AT&T 3B SERIES MACHINES.
C
C      DATA SMALL(1),SMALL(2) /    1048576,          0 /
C      DATA LARGE(1),LARGE(2) / 2146435071,         -1 /
C      DATA RIGHT(1),RIGHT(2) / 1017118720,          0 /
C      DATA DIVER(1),DIVER(2) / 1018167296,          0 /
C      DATA LOG10(1),LOG10(2) / 1070810131, 1352628735 /
C
C     MACHINE CONSTANTS FOR THE IBM PC AND OTHER 8087-ARITHMETIC MICROS
C
C      DATA SMALL(1),SMALL(2) /          0,    1048576 /
C      DATA LARGE(1),LARGE(2) /         -1, 2146435071 /
C      DATA RIGHT(1),RIGHT(2) /          0, 1017118720 /
C      DATA DIVER(1),DIVER(2) /          0, 1018167296 /
C      DATA LOG10(1),LOG10(2) / 1352628735, 1070810131 /
C
C     MACHINE CONSTANTS FOR THE IBM 360/370 SERIES,
C     THE XEROX SIGMA 5/7/9 AND THE SEL SYSTEMS 85/86.
C
C      DATA SMALL(1),SMALL(2) / Z00100000, Z00000000 /
C      DATA LARGE(1),LARGE(2) / Z7FFFFFFF, ZFFFFFFFF /
C      DATA RIGHT(1),RIGHT(2) / Z33100000, Z00000000 /
C      DATA DIVER(1),DIVER(2) / Z34100000, Z00000000 /
C      DATA LOG10(1),LOG10(2) / Z41134413, Z509F79FF /
C
C     MACHINE CONSTANTS FOR THE INTERDATA 8/32
C     WITH THE UNIX SYSTEM FORTRAN 77 COMPILER.
C
C     FOR THE INTERDATA FORTRAN VII COMPILER REPLACE
C     THE Z'S SPECIFYING HEX CONSTANTS WITH Y'S.
C
C      DATA SMALL(1),SMALL(2) / Z'00100000', Z'00000000' /
C      DATA LARGE(1),LARGE(2) / Z'7EFFFFFF', Z'FFFFFFFF' /
C      DATA RIGHT(1),RIGHT(2) / Z'33100000', Z'00000000' /
C      DATA DIVER(1),DIVER(2) / Z'34100000', Z'00000000' /
C      DATA LOG10(1),LOG10(2) / Z'41134413', Z'509F79FF' /
C
C     MACHINE CONSTANTS FOR THE PDP-10 (KA PROCESSOR).
C
C      DATA SMALL(1),SMALL(2) / "033400000000, "000000000000 /
C      DATA LARGE(1),LARGE(2) / "377777777777, "344777777777 /
C      DATA RIGHT(1),RIGHT(2) / "113400000000, "000000000000 /
C      DATA DIVER(1),DIVER(2) / "114400000000, "000000000000 /
C      DATA LOG10(1),LOG10(2) / "177464202324, "144117571776 /
C
C     MACHINE CONSTANTS FOR THE PDP-10 (KI PROCESSOR).
C
C      DATA SMALL(1),SMALL(2) / "000400000000, "000000000000 /
C      DATA LARGE(1),LARGE(2) / "377777777777, "377777777777 /
C      DATA RIGHT(1),RIGHT(2) / "103400000000, "000000000000 /
C      DATA DIVER(1),DIVER(2) / "104400000000, "000000000000 /
C      DATA LOG10(1),LOG10(2) / "177464202324, "047674776746 /
C
C     MACHINE CONSTANTS FOR PDP-11 FORTRANS SUPPORTING
C     32-BIT INTEGERS (EXPRESSED IN INTEGER AND OCTAL).
C
C      DATA SMALL(1),SMALL(2) /    8388608,           0 /
C      DATA LARGE(1),LARGE(2) / 2147483647,          -1 /
C      DATA RIGHT(1),RIGHT(2) /  612368384,           0 /
C      DATA DIVER(1),DIVER(2) /  620756992,           0 /
C      DATA LOG10(1),LOG10(2) / 1067065498, -2063872008 /
C
C      DATA SMALL(1),SMALL(2) / O00040000000, O00000000000 /
C      DATA LARGE(1),LARGE(2) / O17777777777, O37777777777 /
C      DATA RIGHT(1),RIGHT(2) / O04440000000, O00000000000 /
C      DATA DIVER(1),DIVER(2) / O04500000000, O00000000000 /
C      DATA LOG10(1),LOG10(2) / O07746420232, O20476747770 /
C
C     MACHINE CONSTANTS FOR PDP-11 FORTRANS SUPPORTING
C     16-BIT INTEGERS (EXPRESSED IN INTEGER AND OCTAL).
C
C      DATA SMALL(1),SMALL(2) /    128,      0 /
C      DATA SMALL(3),SMALL(4) /      0,      0 /
C
C      DATA LARGE(1),LARGE(2) /  32767,     -1 /
C      DATA LARGE(3),LARGE(4) /     -1,     -1 /
C
C      DATA RIGHT(1),RIGHT(2) /   9344,      0 /
C      DATA RIGHT(3),RIGHT(4) /      0,      0 /
C
C      DATA DIVER(1),DIVER(2) /   9472,      0 /
C      DATA DIVER(3),DIVER(4) /      0,      0 /
C
C      DATA LOG10(1),LOG10(2) /  16282,   8346 /
C      DATA LOG10(3),LOG10(4) / -31493, -12296 /
C
C      DATA SMALL(1),SMALL(2) / O000200, O000000 /
C      DATA SMALL(3),SMALL(4) / O000000, O000000 /
C
C      DATA LARGE(1),LARGE(2) / O077777, O177777 /
C      DATA LARGE(3),LARGE(4) / O177777, O177777 /
C
C      DATA RIGHT(1),RIGHT(2) / O022200, O000000 /
C      DATA RIGHT(3),RIGHT(4) / O000000, O000000 /
C
C      DATA DIVER(1),DIVER(2) / O022400, O000000 /
C      DATA DIVER(3),DIVER(4) / O000000, O000000 /
C
C      DATA LOG10(1),LOG10(2) / O037632, O020232 /
C      DATA LOG10(3),LOG10(4) / O102373, O147770 /
C
C     MACHINE CONSTANTS FOR THE SUN MICROSYSTEMS UNIX F77 COMPILER.
C
      DATA DMACH(1) / 2.22507385850720D-127 /
      DATA DMACH(2) / 1.79769313486231D+127 /
      DATA DMACH(3) / 1.1101827117665D-16 /
      DATA DMACH(4) / 2.2203654423533D-16 /
      DATA DMACH(5) / 3.01029995663981E-1 /
C
C     MACHINE CONSTANTS FOR THE ALLIANT FX/8 UNIX FORTRAN COMPILER.
C
c$$$      DATA DMACH(1) / 2.22507385850721D-308 /
c$$$      DATA DMACH(2) / 1.79769313486231D+308 /
c$$$      DATA DMACH(3) / 1.1101827117665D-16 /
c$$$      DATA DMACH(4) / 2.2203654423533D-16 /
c$$$      DATA DMACH(5) / 3.01029995663981E-1 /
C
C     MACHINE CONSTANTS FOR THE UNIVAC 1100 SERIES.
C
C      DATA SMALL(1),SMALL(2) / O000040000000, O000000000000 /
C      DATA LARGE(1),LARGE(2) / O377777777777, O777777777777 /
C      DATA RIGHT(1),RIGHT(2) / O170540000000, O000000000000 /
C      DATA DIVER(1),DIVER(2) / O170640000000, O000000000000 /
C      DATA LOG10(1),LOG10(2) / O177746420232, O411757177572 /
C
C     MACHINE CONSTANTS FOR THE VAX UNIX F77 COMPILER
C
C      DATA SMALL(1),SMALL(2) /        128,           0 /
C      DATA LARGE(1),LARGE(2) /     -32769,          -1 /
C      DATA RIGHT(1),RIGHT(2) /       9344,           0 /
C      DATA DIVER(1),DIVER(2) /       9472,           0 /
C      DATA LOG10(1),LOG10(2) /  546979738,  -805796613 /
C
C     MACHINE CONSTANTS FOR THE VAX-11 WITH
C     FORTRAN IV-PLUS COMPILER
C
C      DATA SMALL(1),SMALL(2) / Z00000080, Z00000000 /
C      DATA LARGE(1),LARGE(2) / ZFFFF7FFF, ZFFFFFFFF /
C      DATA RIGHT(1),RIGHT(2) / Z00002480, Z00000000 /
C      DATA DIVER(1),DIVER(2) / Z00002500, Z00000000 /
C      DATA LOG10(1),LOG10(2) / Z209A3F9A, ZCFF884FB /
C
C     MACHINE CONSTANTS FOR VAX/VMS VERSION 2.2
C
C      DATA SMALL(1),SMALL(2) /       '80'X,        '0'X /
C      DATA LARGE(1),LARGE(2) / 'FFFF7FFF'X, 'FFFFFFFF'X /
C      DATA RIGHT(1),RIGHT(2) /     '2480'X,        '0'X /
C      DATA DIVER(1),DIVER(2) /     '2500'X,        '0'X /
C      DATA LOG10(1),LOG10(2) / '209A3F9A'X, 'CFF884FB'X /
C
C     MACHINE CONSTANTS FOR THE SEQUENT BALANCE 8000
C
C      DATA SMALL(1),SMALL(2) / $00000000,  $00100000 /
C      DATA LARGE(1),LARGE(2) / $FFFFFFFF,  $7FEFFFFF /
C      DATA RIGHT(1),RIGHT(2) / $00000000,  $3CA00000 /
C      DATA DIVER(1),DIVER(2) / $00000000,  $3CB00000 /
C      DATA LOG10(1),LOG10(2) / $509F79FF,  $3FD34413 /
C
C     MACHINE CONSTANTS FOR SVS FORTRAN ON THE AT&T 7300 (UNIX PC)
C
C      DATA SMALL(1),SMALL(2) / $00100000, $00000000 /
C      DATA LARGE(1),LARGE(2) / $7FEFFFFF, $FFFFFFFF /
C      DATA RIGHT(1),RIGHT(2) / $3CA00000, $00000000 /
C      DATA DIVER(1),DIVER(2) / $3CB00000, $00000000 /
C      DATA LOG10(1),LOG10(2) / $3FD34413, $509F79FF /
C
C     MACHINE CONSTANTS FOR THE RM FORTRAN ON THE AT&T 7300 (UNIX PC)
C
C      DATA SMALL(1),SMALL(2) / Z'00100000', Z'00000000' /
C      DATA LARGE(1),LARGE(2) / Z'7FEFFFFF', Z'FFFFFFFF' /
C      DATA RIGHT(1),RIGHT(2) / Z'3CA00000', Z'00000000' /
C      DATA DIVER(1),DIVER(2) / Z'3CB00000', Z'00000000' /
C      DATA LOG10(1),LOG10(2) / Z'3FD34413', Z'509F79FF' /
C
      IF (I .LT. 1  .OR.  I .GT. 5) GOTO 999
      D1MACH = DMACH(I)
      RETURN
  999 WRITE(I1MACH(2),1999) I
 1999 FORMAT(' D1MACH - I OUT OF BOUNDS',I10)
      STOP
      END
      INTEGER FUNCTION I1MACH(I)
C
C  I/O UNIT NUMBERS.
C
C    I1MACH( 1) = THE STANDARD INPUT UNIT.
C
C    I1MACH( 2) = THE STANDARD OUTPUT UNIT.
C
C    I1MACH( 3) = THE STANDARD PUNCH UNIT.
C
C    I1MACH( 4) = THE STANDARD ERROR MESSAGE UNIT.
C
C  WORDS.
C
C    I1MACH( 5) = THE NUMBER OF BITS PER INTEGER STORAGE UNIT.
C
C    I1MACH( 6) = THE NUMBER OF CHARACTERS PER INTEGER STORAGE UNIT.
C
C  INTEGERS.
C
C    ASSUME INTEGERS ARE REPRESENTED IN THE S-DIGIT, BASE-A FORM
C
C               SIGN ( X(S-1)*A**(S-1) + ... + X(1)*A + X(0) )
C
C               WHERE 0 .LE. X(I) .LT. A FOR I=0,...,S-1.
C
C    I1MACH( 7) = A, THE BASE.
C
C    I1MACH( 8) = S, THE NUMBER OF BASE-A DIGITS.
C
C    I1MACH( 9) = A**S - 1, THE LARGEST MAGNITUDE.
C
C  FLOATING-POINT NUMBERS.
C
C    ASSUME FLOATING-POINT NUMBERS ARE REPRESENTED IN THE T-DIGIT,
C    BASE-B FORM
C
C               SIGN (B**E)*( (X(1)/B) + ... + (X(T)/B**T) )
C
C               WHERE 0 .LE. X(I) .LT. B FOR I=1,...,T,
C               0 .LT. X(1), AND EMIN .LE. E .LE. EMAX.
C
C    I1MACH(10) = B, THE BASE.
C
C  SINGLE-PRECISION
C
C    I1MACH(11) = T, THE NUMBER OF BASE-B DIGITS.
C
C    I1MACH(12) = EMIN, THE SMALLEST EXPONENT E.
C
C    I1MACH(13) = EMAX, THE LARGEST EXPONENT E.
C
C  DOUBLE-PRECISION
C
C    I1MACH(14) = T, THE NUMBER OF BASE-B DIGITS.
C
C    I1MACH(15) = EMIN, THE SMALLEST EXPONENT E.
C
C    I1MACH(16) = EMAX, THE LARGEST EXPONENT E.
C
C  TO ALTER THIS FUNCTION FOR A PARTICULAR ENVIRONMENT,
C  THE DESIRED SET OF DATA STATEMENTS SHOULD BE ACTIVATED BY
C  REMOVING THE C FROM COLUMN 1.  ALSO, THE VALUES OF
C  I1MACH(1) - I1MACH(4) SHOULD BE CHECKED FOR CONSISTENCY
C  WITH THE LOCAL OPERATING SYSTEM.
C  ON RARE MACHINES A STATIC STATEMENT MAY NEED TO BE ADDED.
C  (BUT PROBABLY MORE SYSTEMS PROHIBIT IT THAN REQUIRE IT.)
C
      INTEGER IMACH(16),OUTPUT
C
      EQUIVALENCE (IMACH(4),OUTPUT)
C
C     MACHINE CONSTANTS FOR THE BURROUGHS 1700 SYSTEM.
C
C      DATA IMACH( 1) /    7 /
C      DATA IMACH( 2) /    2 /
C      DATA IMACH( 3) /    2 /
C      DATA IMACH( 4) /    2 /
C      DATA IMACH( 5) /   36 /
C      DATA IMACH( 6) /    4 /
C      DATA IMACH( 7) /    2 /
C      DATA IMACH( 8) /   33 /
C      DATA IMACH( 9) / Z1FFFFFFFF /
C      DATA IMACH(10) /    2 /
C      DATA IMACH(11) /   24 /
C      DATA IMACH(12) / -256 /
C      DATA IMACH(13) /  255 /
C      DATA IMACH(14) /   60 /
C      DATA IMACH(15) / -256 /
C      DATA IMACH(16) /  255 /
C
C     MACHINE CONSTANTS FOR THE BURROUGHS 5700 SYSTEM.
C
C      DATA IMACH( 1) /   5 /
C      DATA IMACH( 2) /   6 /
C      DATA IMACH( 3) /   7 /
C      DATA IMACH( 4) /   6 /
C      DATA IMACH( 5) /  48 /
C      DATA IMACH( 6) /   6 /
C      DATA IMACH( 7) /   2 /
C      DATA IMACH( 8) /  39 /
C      DATA IMACH( 9) / O0007777777777777 /
C      DATA IMACH(10) /   8 /
C      DATA IMACH(11) /  13 /
C      DATA IMACH(12) / -50 /
C      DATA IMACH(13) /  76 /
C      DATA IMACH(14) /  26 /
C      DATA IMACH(15) / -50 /
C      DATA IMACH(16) /  76 /
C
C     MACHINE CONSTANTS FOR THE BURROUGHS 6700/7700 SYSTEMS.
C
C      DATA IMACH( 1) /   5 /
C      DATA IMACH( 2) /   6 /
C      DATA IMACH( 3) /   7 /
C      DATA IMACH( 4) /   6 /
C      DATA IMACH( 5) /  48 /
C      DATA IMACH( 6) /   6 /
C      DATA IMACH( 7) /   2 /
C      DATA IMACH( 8) /  39 /
C      DATA IMACH( 9) / O0007777777777777 /
C      DATA IMACH(10) /   8 /
C      DATA IMACH(11) /  13 /
C      DATA IMACH(12) / -50 /
C      DATA IMACH(13) /  76 /
C      DATA IMACH(14) /  26 /
C      DATA IMACH(15) / -32754 /
C      DATA IMACH(16) /  32780 /
C
C     MACHINE CONSTANTS FOR THE CDC 6000/7000 SERIES.
C
C      DATA IMACH( 1) /    5 /
C      DATA IMACH( 2) /    6 /
C      DATA IMACH( 3) /    7 /
C      DATA IMACH( 4) /    6 /
C      DATA IMACH( 5) /   60 /
C      DATA IMACH( 6) /   10 /
C      DATA IMACH( 7) /    2 /
C      DATA IMACH( 8) /   48 /
C      DATA IMACH( 9) / 00007777777777777777B /
C      DATA IMACH(10) /    2 /
C      DATA IMACH(11) /   48 /
C      DATA IMACH(12) / -974 /
C      DATA IMACH(13) / 1070 /
C      DATA IMACH(14) /   96 /
C      DATA IMACH(15) / -927 /
C      DATA IMACH(16) / 1070 /
C
C     MACHINE CONSTANTS FOR CONVEX C-1
C
C      DATA IMACH( 1) /    5 /
C      DATA IMACH( 2) /    6 /
C      DATA IMACH( 3) /    7 /
C      DATA IMACH( 4) /    6 /
C      DATA IMACH( 5) /   32 /
C      DATA IMACH( 6) /    4 /
C      DATA IMACH( 7) /    2 /
C      DATA IMACH( 8) /   31 /
C      DATA IMACH( 9) / 2147483647 /
C      DATA IMACH(10) /    2 /
C      DATA IMACH(11) /   24 /
C      DATA IMACH(12) / -128 /
C      DATA IMACH(13) /  127 /
C      DATA IMACH(14) /   53 /
C      DATA IMACH(15) /-1024 /
C      DATA IMACH(16) / 1023 /
C
C     MACHINE CONSTANTS FOR THE CRAY 1
C
C      DATA IMACH( 1) /     5 /
C      DATA IMACH( 2) /     6 /
C      DATA IMACH( 3) /   102 /
C      DATA IMACH( 4) /     6 /
C      DATA IMACH( 5) /    64 /
C      DATA IMACH( 6) /     8 /
C      DATA IMACH( 7) /     2 /
C      DATA IMACH( 8) /    46 /
C      DATA IMACH( 9) /  1777777777777777B /
C      DATA IMACH(10) /     2 /
C      DATA IMACH(11) /    47 /
C      DATA IMACH(12) / -8189 /
C      DATA IMACH(13) /  8190 /
C      DATA IMACH(14) /    94 /
C      DATA IMACH(15) / -8099 /
C      DATA IMACH(16) /  8190 /
C
C     MACHINE CONSTANTS FOR THE DATA GENERAL ECLIPSE S/200
C
C      DATA IMACH( 1) /   11 /
C      DATA IMACH( 2) /   12 /
C      DATA IMACH( 3) /    8 /
C      DATA IMACH( 4) /   10 /
C      DATA IMACH( 5) /   16 /
C      DATA IMACH( 6) /    2 /
C      DATA IMACH( 7) /    2 /
C      DATA IMACH( 8) /   15 /
C      DATA IMACH( 9) /32767 /
C      DATA IMACH(10) /   16 /
C      DATA IMACH(11) /    6 /
C      DATA IMACH(12) /  -64 /
C      DATA IMACH(13) /   63 /
C      DATA IMACH(14) /   14 /
C      DATA IMACH(15) /  -64 /
C      DATA IMACH(16) /   63 /
C
C     MACHINE CONSTANTS FOR THE HARRIS SLASH 6 AND SLASH 7
C
C      DATA IMACH( 1) /       5 /
C      DATA IMACH( 2) /       6 /
C      DATA IMACH( 3) /       0 /
C      DATA IMACH( 4) /       6 /
C      DATA IMACH( 5) /      24 /
C      DATA IMACH( 6) /       3 /
C      DATA IMACH( 7) /       2 /
C      DATA IMACH( 8) /      23 /
C      DATA IMACH( 9) / 8388607 /
C      DATA IMACH(10) /       2 /
C      DATA IMACH(11) /      23 /
C      DATA IMACH(12) /    -127 /
C      DATA IMACH(13) /     127 /
C      DATA IMACH(14) /      38 /
C      DATA IMACH(15) /    -127 /
C      DATA IMACH(16) /     127 /
C
C     MACHINE CONSTANTS FOR THE HONEYWELL DPS 8/70 SERIES.
C
C      DATA IMACH( 1) /    5 /
C      DATA IMACH( 2) /    6 /
C      DATA IMACH( 3) /   43 /
C      DATA IMACH( 4) /    6 /
C      DATA IMACH( 5) /   36 /
C      DATA IMACH( 6) /    4 /
C      DATA IMACH( 7) /    2 /
C      DATA IMACH( 8) /   35 /
C      DATA IMACH( 9) / O377777777777 /
C      DATA IMACH(10) /    2 /
C      DATA IMACH(11) /   27 /
C      DATA IMACH(12) / -127 /
C      DATA IMACH(13) /  127 /
C      DATA IMACH(14) /   63 /
C      DATA IMACH(15) / -127 /
C      DATA IMACH(16) /  127 /
C
C     MACHINE CONSTANTS FOR IEEE ARITHMETIC MACHINES (E.G., AT&T 3B
C     SERIES COMPUTERS AND 8087-BASED MACHINES LIKE THE IBM PC).
C
C      DATA IMACH( 1) /    5 /
C      DATA IMACH( 2) /    6 /
C      DATA IMACH( 3) /    7 /
C      DATA IMACH( 4) /    6 /
C      DATA IMACH( 5) /   32 /
C      DATA IMACH( 6) /    4 /
C      DATA IMACH( 7) /    2 /
C      DATA IMACH( 8) /   31 /
C      DATA IMACH( 9) / 2147483647 /
C      DATA IMACH(10) /    2 /
C      DATA IMACH(11) /   24 /
C      DATA IMACH(12) / -125 /
C      DATA IMACH(13) /  128 /
C      DATA IMACH(14) /   53 /
C      DATA IMACH(15) / -1021 /
C      DATA IMACH(16) /  1024 /
C
C     MACHINE CONSTANTS FOR THE IBM 360/370 SERIES,
C     THE XEROX SIGMA 5/7/9 AND THE SEL SYSTEMS 85/86.
C
C      DATA IMACH( 1) /   5 /
C      DATA IMACH( 2) /   6 /
C      DATA IMACH( 3) /   7 /
C      DATA IMACH( 4) /   6 /
C      DATA IMACH( 5) /  32 /
C      DATA IMACH( 6) /   4 /
C      DATA IMACH( 7) /   2 /
C      DATA IMACH( 8) /  31 /
C      DATA IMACH( 9) / Z7FFFFFFF /
C      DATA IMACH(10) /  16 /
C      DATA IMACH(11) /   6 /
C      DATA IMACH(12) / -64 /
C      DATA IMACH(13) /  63 /
C      DATA IMACH(14) /  14 /
C      DATA IMACH(15) / -64 /
C      DATA IMACH(16) /  63 /
C
C     MACHINE CONSTANTS FOR THE INTERDATA 8/32
C     WITH THE UNIX SYSTEM FORTRAN 77 COMPILER.
C
C     FOR THE INTERDATA FORTRAN VII COMPILER REPLACE
C     THE Z'S SPECIFYING HEX CONSTANTS WITH Y'S.
C
C      DATA IMACH( 1) /   5 /
C      DATA IMACH( 2) /   6 /
C      DATA IMACH( 3) /   6 /
C      DATA IMACH( 4) /   6 /
C      DATA IMACH( 5) /  32 /
C      DATA IMACH( 6) /   4 /
C      DATA IMACH( 7) /   2 /
C      DATA IMACH( 8) /  31 /
C      DATA IMACH( 9) / Z'7FFFFFFF' /
C      DATA IMACH(10) /  16 /
C      DATA IMACH(11) /   6 /
C      DATA IMACH(12) / -64 /
C      DATA IMACH(13) /  62 /
C      DATA IMACH(14) /  14 /
C      DATA IMACH(15) / -64 /
C      DATA IMACH(16) /  62 /
C
C     MACHINE CONSTANTS FOR THE PDP-10 (KA PROCESSOR).
C
C      DATA IMACH( 1) /    5 /
C      DATA IMACH( 2) /    6 /
C      DATA IMACH( 3) /    7 /
C      DATA IMACH( 4) /    6 /
C      DATA IMACH( 5) /   36 /
C      DATA IMACH( 6) /    5 /
C      DATA IMACH( 7) /    2 /
C      DATA IMACH( 8) /   35 /
C      DATA IMACH( 9) / "377777777777 /
C      DATA IMACH(10) /    2 /
C      DATA IMACH(11) /   27 /
C      DATA IMACH(12) / -128 /
C      DATA IMACH(13) /  127 /
C      DATA IMACH(14) /   54 /
C      DATA IMACH(15) / -101 /
C      DATA IMACH(16) /  127 /
C
C     MACHINE CONSTANTS FOR THE PDP-10 (KI PROCESSOR).
C
C      DATA IMACH( 1) /    5 /
C      DATA IMACH( 2) /    6 /
C      DATA IMACH( 3) /    7 /
C      DATA IMACH( 4) /    6 /
C      DATA IMACH( 5) /   36 /
C      DATA IMACH( 6) /    5 /
C      DATA IMACH( 7) /    2 /
C      DATA IMACH( 8) /   35 /
C      DATA IMACH( 9) / "377777777777 /
C      DATA IMACH(10) /    2 /
C      DATA IMACH(11) /   27 /
C      DATA IMACH(12) / -128 /
C      DATA IMACH(13) /  127 /
C      DATA IMACH(14) /   62 /
C      DATA IMACH(15) / -128 /
C      DATA IMACH(16) /  127 /
C
C     MACHINE CONSTANTS FOR PDP-11 FORTRANS SUPPORTING
C     32-BIT INTEGER ARITHMETIC.
C
C      DATA IMACH( 1) /    5 /
C      DATA IMACH( 2) /    6 /
C      DATA IMACH( 3) /    7 /
C      DATA IMACH( 4) /    6 /
C      DATA IMACH( 5) /   32 /
C      DATA IMACH( 6) /    4 /
C      DATA IMACH( 7) /    2 /
C      DATA IMACH( 8) /   31 /
C      DATA IMACH( 9) / 2147483647 /
C      DATA IMACH(10) /    2 /
C      DATA IMACH(11) /   24 /
C      DATA IMACH(12) / -127 /
C      DATA IMACH(13) /  127 /
C      DATA IMACH(14) /   56 /
C      DATA IMACH(15) / -127 /
C      DATA IMACH(16) /  127 /
C
C     MACHINE CONSTANTS FOR PDP-11 FORTRANS SUPPORTING
C     16-BIT INTEGER ARITHMETIC.
C
C      DATA IMACH( 1) /    5 /
C      DATA IMACH( 2) /    6 /
C      DATA IMACH( 3) /    7 /
C      DATA IMACH( 4) /    6 /
C      DATA IMACH( 5) /   16 /
C      DATA IMACH( 6) /    2 /
C      DATA IMACH( 7) /    2 /
C      DATA IMACH( 8) /   15 /
C      DATA IMACH( 9) / 32767 /
C      DATA IMACH(10) /    2 /
C      DATA IMACH(11) /   24 /
C      DATA IMACH(12) / -127 /
C      DATA IMACH(13) /  127 /
C      DATA IMACH(14) /   56 /
C      DATA IMACH(15) / -127 /
C      DATA IMACH(16) /  127 /
C
C     MACHINE CONSTANTS FOR THE SUN MICROSYSTEMS UNIX F77 COMPILER.
C
      DATA IMACH( 1) /     5 /
      DATA IMACH( 2) /     6 /
      DATA IMACH( 3) /     6 /
      DATA IMACH( 4) /     0 /
      DATA IMACH( 5) /    32 /
      DATA IMACH( 6) /     4 /
      DATA IMACH( 7) /     2 /
      DATA IMACH( 8) /    32 /
      DATA IMACH( 9) /2147483647/
      DATA IMACH(10) /     2 /
      DATA IMACH(11) /    24 /
      DATA IMACH(12) /  -126 /
      DATA IMACH(13) /   128 /
      DATA IMACH(14) /    53 /
      DATA IMACH(15) / -1022 /
      DATA IMACH(16) /  1024 /
C
C     MACHINE CONSTANTS FOR THE ALLIANT FX/8 UNIX FORTRAN COMPILER.
C
c$$$      DATA IMACH( 1) /     5 /
c$$$      DATA IMACH( 2) /     6 /
c$$$      DATA IMACH( 3) /     6 /
c$$$      DATA IMACH( 4) /     0 /
c$$$      DATA IMACH( 5) /    32 /
c$$$      DATA IMACH( 6) /     4 /
c$$$      DATA IMACH( 7) /     2 /
c$$$      DATA IMACH( 8) /    32 /
c$$$      DATA IMACH( 9) /2147483647/
c$$$      DATA IMACH(10) /     2 /
c$$$      DATA IMACH(11) /    24 /
c$$$      DATA IMACH(12) /  -126 /
c$$$      DATA IMACH(13) /   128 /
c$$$      DATA IMACH(14) /    53 /
c$$$      DATA IMACH(15) / -1022 /
c$$$      DATA IMACH(16) /  1024 /
C
C     MACHINE CONSTANTS FOR THE ALLIANT FX/8 UNIX FORTRAN COMPILER.
C     WITH THE -r8 COMMAND LINE OPTION.
C
c$$$      DATA IMACH( 1) /     5 /
c$$$      DATA IMACH( 2) /     6 /
c$$$      DATA IMACH( 3) /     6 /
c$$$      DATA IMACH( 4) /     0 /
c$$$      DATA IMACH( 5) /    32 /
c$$$      DATA IMACH( 6) /     4 /
c$$$      DATA IMACH( 7) /     2 /
c$$$      DATA IMACH( 8) /    32 /
c$$$      DATA IMACH( 9) /2147483647/
c$$$      DATA IMACH(10) /     2 /
c$$$      DATA IMACH(11) /    53 /
c$$$      DATA IMACH(12) / -1022 /
c$$$      DATA IMACH(13) /  1024 /
c$$$      DATA IMACH(14) /    53 /
c$$$      DATA IMACH(15) / -1022 /
c$$$      DATA IMACH(16) /  1024 /
C
C     MACHINE CONSTANTS FOR THE UNIVAC 1100 SERIES.
C
C     NOTE THAT THE PUNCH UNIT, I1MACH(3), HAS BEEN SET TO 7
C     WHICH IS APPROPRIATE FOR THE UNIVAC-FOR SYSTEM.
C     IF YOU HAVE THE UNIVAC-FTN SYSTEM, SET IT TO 1.
C
C      DATA IMACH( 1) /    5 /
C      DATA IMACH( 2) /    6 /
C      DATA IMACH( 3) /    7 /
C      DATA IMACH( 4) /    6 /
C      DATA IMACH( 5) /   36 /
C      DATA IMACH( 6) /    6 /
C      DATA IMACH( 7) /    2 /
C      DATA IMACH( 8) /   35 /
C      DATA IMACH( 9) / O377777777777 /
C      DATA IMACH(10) /    2 /
C      DATA IMACH(11) /   27 /
C      DATA IMACH(12) / -128 /
C      DATA IMACH(13) /  127 /
C      DATA IMACH(14) /   60 /
C      DATA IMACH(15) /-1024 /
C      DATA IMACH(16) / 1023 /
C
C     MACHINE CONSTANTS FOR VAX
C
C      DATA IMACH( 1) /    5 /
C      DATA IMACH( 2) /    6 /
C      DATA IMACH( 3) /    7 /
C      DATA IMACH( 4) /    6 /
C      DATA IMACH( 5) /   32 /
C      DATA IMACH( 6) /    4 /
C      DATA IMACH( 7) /    2 /
C      DATA IMACH( 8) /   31 /
C      DATA IMACH( 9) / 2147483647 /
C      DATA IMACH(10) /    2 /
C      DATA IMACH(11) /   24 /
C      DATA IMACH(12) / -127 /
C      DATA IMACH(13) /  127 /
C      DATA IMACH(14) /   56 /
C      DATA IMACH(15) / -127 /
C      DATA IMACH(16) /  127 /
C
C     MACHINE CONSTANTS FOR THE SEQUENT BALANCE 8000 AND SVS FORTRAN ON
C     THE AT&T 7300 (UNIX PC)
C
C      DATA IMACH( 1) /     0 /
C      DATA IMACH( 2) /     0 /
C      DATA IMACH( 3) /     7 /
C      DATA IMACH( 4) /     0 /
C      DATA IMACH( 5) /    32 /
C      DATA IMACH( 6) /     1 /
C      DATA IMACH( 7) /     2 /
C      DATA IMACH( 8) /    31 /
C      DATA IMACH( 9) /  2147483647 /
C      DATA IMACH(10) /     2 /
C      DATA IMACH(11) /    24 /
C      DATA IMACH(12) /  -125 /
C      DATA IMACH(13) /   128 /
C      DATA IMACH(14) /    53 /
C      DATA IMACH(15) / -1021 /
C      DATA IMACH(16) /  1024 /
C
C     MACHINE CONSTANTS FOR THE RM FORTRAN ON THE AT&T 7300 (UNIX PC)
C
C      DATA IMACH( 1) /     5 /
C      DATA IMACH( 2) /     6 /
C      DATA IMACH( 3) /     7 /
C      DATA IMACH( 4) /     6 /
C      DATA IMACH( 5) /    32 /
C      DATA IMACH( 6) /     1 /
C      DATA IMACH( 7) /     2 /
C      DATA IMACH( 8) /    31 /
C      DATA IMACH( 9) /  2147483647 /
C      DATA IMACH(10) /     2 /
C      DATA IMACH(11) /    24 /
C      DATA IMACH(12) /  -125 /
C      DATA IMACH(13) /   128 /
C      DATA IMACH(14) /    53 /
C      DATA IMACH(15) / -1021 /
C      DATA IMACH(16) /  1024 /
C
      IF (I .LT. 1  .OR.  I .GT. 16) GO TO 999
      I1MACH=IMACH(I)
      RETURN
  999 WRITE(OUTPUT,1999) I
 1999 FORMAT(' I1MACH - I OUT OF BOUNDS',I10)
      STOP
      END